TopView Snapshot Report ValuesViewMobile

Created: 4/24/2024 2:32:00 AM


Tag value 161.00
Status Good
Units Deg F
Time stamp 4/24/2024 2:31:59 AM
Description Outlet temperature
Alarm limits >150 OR <130
Time in alarm (disabled)
Time of alarm (disabled)
Primary tag group Unit1\Temperature
Priority 1
Custom field 1 AlarmInfo
Custom field 2 AlarmInfo


Tag value 162.8
Status Good
Units Deg F
Time stamp 4/24/2024 2:31:59 AM
Description Avg outlet temp
Alarm limits
Time in alarm (disabled)
Time of alarm (disabled)
Primary tag group Unit1\Temperature
Priority 1
Custom field 1
Custom field 2


* Unacknowledged
Tag value OK
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Level 1 indicator
Alarm limits =HI (DelayIn=10s)
Time in alarm 000:00:10
Time of alarm 4/24/2024 2:31:39 AM
Primary tag group Unit1\Level\Indicator 1
Priority 1
Custom field 1
Custom field 2


HIHI * Unacknowledged
Tag value HIHI
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Level 2 indicator
Alarm limits =HIHI
Time in alarm 000:00:10
Time of alarm 4/24/2024 2:31:49 AM
Primary tag group Unit1\Level\Indicator 2
Priority 1
Custom field 1
Custom field 2


Tag value Stopped
Status Good
Units State
Time stamp 4/24/2024 2:31:59 AM
Description Discharge Pump 1
Alarm limits
Time in alarm
Time of alarm
Primary tag group Unit1\Pump
Priority 1
Custom field 1
Custom field 2


* Unacknowledged
Tag value Stopped
Status Good
Units State
Time stamp 4/24/2024 2:31:59 AM
Description Discharge Pump 2
Alarm limits =RUNNING
Time in alarm 000:01:00
Time of alarm 4/24/2024 2:30:59 AM
Primary tag group Unit2\Pump
Priority 1
Custom field 1
Custom field 2


Tag value 148.1
Status Good
Units psi
Time stamp 4/24/2024 2:31:59 AM
Description Outlet 4 pressure
Alarm limits
Time in alarm
Time of alarm
Primary tag group Pressure
Priority 1
Custom field 1
Custom field 2


Tag value 154.2
Status Good
Units psi
Time stamp 4/24/2024 2:31:59 AM
Description Outlet 5 pressure
Alarm limits
Time in alarm
Time of alarm
Primary tag group Pressure
Priority 5
Custom field 1
Custom field 2


Tag value 169.2
Status Good
Units Deg F
Time stamp 4/24/2024 2:31:59 AM
Description Outlet 4 temperature
Alarm limits
Time in alarm
Time of alarm
Primary tag group Unit1\Temperature
Priority 1
Custom field 1
Custom field 2


Tag value 170.3
Status Good
Units Deg F
Time stamp 4/24/2024 2:31:59 AM
Description Outlet 5 temperature
Alarm limits
Time in alarm
Time of alarm
Primary tag group Unit1\Temperature
Priority 1
Custom field 1
Custom field 2


Tag value Up
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Station 4 status
Alarm limits =DOWN
Time in alarm
Time of alarm
Primary tag group Station Status
Priority 1
Custom field 1
Custom field 2


Information
Tag value Down
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Station 5 status
Alarm limits =DOWN
Time in alarm 3302:30:27
Time of alarm 12/8/2023 11:01:32 AM
Primary tag group Station Status
Priority 1
Custom field 1
Custom field 2


Information
Tag value Down
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Station 6 status
Alarm limits =DOWN
Time in alarm 3302:30:27
Time of alarm 12/8/2023 11:01:32 AM
Primary tag group Station Status
Priority 1
Custom field 1
Custom field 2


Warning
Tag value 220
Status Good
Units ppm
Time stamp 4/24/2024 2:31:59 AM
Description Unit1 NOx
Alarm limits >100
Time in alarm 3302:30:27
Time of alarm 12/8/2023 11:01:32 AM
Primary tag group NOx
Priority 1
Custom field 1
Custom field 2


Tag value 221
Status Good
Units ppm
Time stamp 4/24/2024 2:31:59 AM
Description Unit 2 NOx
Alarm limits
Time in alarm
Time of alarm
Primary tag group NOx
Priority 1
Custom field 1
Custom field 2


High
Tag value 167
Status Good
Units MW
Time stamp 4/24/2024 2:31:59 AM
Description Unit 1 power
Alarm limits >165
Time in alarm 3302:30:27
Time of alarm 12/8/2023 11:01:32 AM
Primary tag group Power
Priority 1
Custom field 1
Custom field 2


* Unacknowledged
Tag value 161
Status Good
Units MW
Time stamp 4/24/2024 2:31:59 AM
Description Unit 2 power
Alarm limits >167 Configured: >'TopView.Dev1.Power_Unit_1'
Time in alarm 000:00:45
Time of alarm 4/24/2024 2:27:24 AM
Primary tag group Power
Priority 1
Custom field 1
Custom field 2


* Unacknowledged
Tag value 1.000
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Operation running
Alarm limits =1
Time in alarm 3302:30:27
Time of alarm 12/8/2023 11:01:32 AM
Primary tag group OperationStatus
Priority 1
Custom field 1
Custom field 2


Tag value 441.125
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description
Alarm limits
Time in alarm
Time of alarm
Primary tag group
Priority 1
Custom field 1
Custom field 2


Tag value 0.000
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Current number of SNMP Trap msgs sent that failed since TopView was started
Alarm limits
Time in alarm
Time of alarm
Primary tag group
Priority 1
Custom field 1
Custom field 2


Tag value 0.000
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Current number of msgs in the outgoing SNMP Trap queue
Alarm limits
Time in alarm
Time of alarm
Primary tag group
Priority 1
Custom field 1
Custom field 2


Tag value 0.000
Status Good
Units
Time stamp 4/24/2024 2:31:59 AM
Description Total number of SNMP Trap msgs sent since TopView was started
Alarm limits
Time in alarm
Time of alarm
Primary tag group
Priority 1
Custom field 1
Custom field 2

  1. Alarm: Level 2 indicator alarm
  2. Alarm: Station number 5 is down
  3. Alarm: Station number 6 is down
  4. Alarm: Unit 1 NOX emissions, 225, is too high
  5. Alarm: Unit 1 power output, 169, is greater than 165
  6. Alarm: OperationRunning (1.000) = 1