State Current value Status Units Time Description Alarm limits Time in alarm Time of alarm Primary Group Priority Custom1 Custom2
Disabled 165.50 Good Deg F 3/29/2024 10:47:55 AM Outlet temperature >150 OR <130 (disabled) (disabled) Unit1\Temperature 1 AlarmInfo AlarmInfo
Disabled 164.7 Good Deg F 3/29/2024 10:47:55 AM Avg outlet temp (disabled) (disabled) Unit1\Temperature 1
Warning * HI Good 3/29/2024 10:47:55 AM Level 1 indicator =HI (DelayIn=10s) 000:00:05 3/29/2024 10:47:51 AM Unit1\Level\Indicator 1 1
* HI Good 3/29/2024 10:47:55 AM Level 2 indicator =HIHI 000:00:40 3/29/2024 10:47:01 AM Unit1\Level\Indicator 2 1
Running Good State 3/29/2024 10:47:55 AM Discharge Pump 1 Unit1\Pump 1
Information * Running Good State 3/29/2024 10:47:55 AM Discharge Pump 2 =RUNNING 000:00:25 3/29/2024 10:47:31 AM Unit2\Pump 1
145.1 Good psi 3/29/2024 10:47:55 AM Outlet 4 pressure Pressure 1
156.0 Good psi 3/29/2024 10:47:55 AM Outlet 5 pressure Pressure 5
171.3 Good Deg F 3/29/2024 10:47:55 AM Outlet 4 temperature Unit1\Temperature 1
167.3 Good Deg F 3/29/2024 10:47:55 AM Outlet 5 temperature Unit1\Temperature 1
Up Good 3/29/2024 10:47:55 AM Station 4 status =DOWN Station Status 1
Information Down Good 3/29/2024 10:47:55 AM Station 5 status =DOWN 2686:46:23 12/8/2023 11:01:32 AM Station Status 1
Information Down Good 3/29/2024 10:47:55 AM Station 6 status =DOWN 2686:46:23 12/8/2023 11:01:32 AM Station Status 1
Warning 224 Good ppm 3/29/2024 10:47:55 AM Unit1 NOx >100 2686:46:23 12/8/2023 11:01:32 AM NOx 1
223 Good ppm 3/29/2024 10:47:55 AM Unit 2 NOx NOx 1
High 166 Good MW 3/29/2024 10:47:55 AM Unit 1 power >165 2686:46:23 12/8/2023 11:01:32 AM Power 1
* 161 Good MW 3/29/2024 10:47:55 AM Unit 2 power >166 Configured: >'TopView.Dev1.Power_Unit_1' 000:00:20 3/29/2024 10:42:50 AM Power 1
* 1.000 Good 3/29/2024 10:47:56 AM Operation running =1 2686:46:23 12/8/2023 11:01:32 AM OperationStatus 1
447.450 Good 3/29/2024 10:47:56 AM 1
0.000 Good 3/29/2024 10:47:56 AM Current number of SNMP Trap msgs sent that failed since TopView was started 1
0.000 Good 3/29/2024 10:47:56 AM Current number of msgs in the outgoing SNMP Trap queue 1
0.000 Good 3/29/2024 10:47:56 AM Total number of SNMP Trap msgs sent since TopView was started 1
  1. Alarm: Level 1 indicator alarm
  2. Alarm: Discharge pump 2 is running
  3. Alarm: Station number 5 is down
  4. Alarm: Station number 6 is down
  5. Alarm: Unit 1 NOX emissions, 225, is too high
  6. Alarm: Unit 1 power output, 169, is greater than 165
  7. Alarm: OperationRunning (1.000) = 1